si_pump_to(0): PUMP T.O. BSTATE DISABLED.

When a transmission is completed on a port, the fep shuts the line down and then automatically repumps the board. This alarm indicates that there was a problem with that automatic repump.

Check the logs:

ncxu_root-> grep pump /usr/attmail/logs/*cu* 
  Jan  8 00:06:59+FYI+ +shworks+line5.0+hiisc5.0+639+ +is78+Executing 
  /usr/lib/lu62/s2_pump /dev/si1 /usr/lib/lu62/s2_load 
  /usr/lib/lu62/flasher. 
  Jan  8 01:09:02+FYI+ +shworks+line5.0+hiisc5.0+639+ +is78+Executing 
  /usr/lib/lu62/s2_pump /dev/si1 /usr/lib/lu62/s2_load 
  /usr/lib/lu62/flasher. 
  Jan  8 02:10:58+FYI+ +shworks+line5.0+hiisc5.0+639+ +is78+Executing  
  /usr/lib/lu62/s2_pump /dev/si1 /usr/lib/lu62/s2_load    
  /usr/lib/lu62/flasher. 
  Jan  8 03:12:56+FYI+ +shworks+line5.0+hiisc5.0+639+ +is78+Executing    
  /usr/lib/lu62/s2_pump /dev/si1 /usr/lib/lu62/s2_load   
  /usr/lib/lu62/flasher. 

Resolve it by repumping the line:

ncxu_root-> hiportstop line5.0 
ncxu_root-> repump line5.0 
ncxu_root-> hiportstart line5.0 
     hiisc5.0 DIRECT & 

This usually resolves the problem.


PythonPowered EditText of this page (last modified 2003-07-16 20:53:48)
FindPage by title search or text search