GMS NOC Docs   Ring No Ans UserPreferences
 
Help Search Diffs Info Edit Subscribe Print View
 GMS NOC Docs   FrontPage   RecentChanges   TitleIndex   Help 

Ring No Ans

[brnet206] 2/21/31 13:00 99 Ring No Ans 48/10

We can check on this using Starkeeper, a system used for monitoring the [FOLDOC]DataKit switches.

We're interested in line 99 on brnet206.

Is something excessively high (30s) or low (0s)?

disco 99 -- shows disconnects, doesn't actually do it disconnect 99 -- actually does the disconnect

To actually do something about this, instead of just having the faulty line be passed over,

SK: setn sx 
sx>
The sx> prompt indicates we are on the sx datakit.
sx> disp con mod66/11 
Display console module. The 66/11 comes from the netwatch book's list faxed to us. This shows the ports on the module.
sx> vfy mod 66/11 
If DEAD,
sx> rem sx 66/11 5 
(5 is the port number) to restore, res

/!\ work needed


PythonPowered EditText of this page (last modified 2003-07-16 20:53:32)